What it says, in HSE's own words
The problem While considering the implementation of a noise control programme, a major soft drinks manufacturer was advised that a pump used for transferring fruit juice concentrate from 200 litre drums to the product mixing tanks was producing A-weighted noise levels of 103 dB. The solution A preliminary inspection showed mechanical deterioration of the pump which required a complete overhaul to include: rewinding the drive motor; replacing the motor bearings; checking and cleaning the pump bearings; repacking the pump glands.
Nominal costs for staff time. (1995) The result A noise reduction of 27 dB. Source Report details supplied by Sound Research Laboratories Limited, Wilmslow.